60 Amp Subpanel Wire Size for 60 Feet (Shed / Garage)

Quick Answer: Use 6 AWG Copper (6/3 NM-B) or 4 AWG Aluminum with a 60 Amp 2-Pole Breaker. A 60 Amp subpanel located 60 feet from the main service panel requires 6 AWG copper (rated 65A in THHN, or 55A NM-B rounded up to 60A breaker) or 4 AWG aluminum SER.

⚠️ Electrical Safety Notice: Always turn off the main service breaker and verify zero voltage with a non-contact tester before working inside any electrical panel.

⚡ Interactive NEC Wire Size & Voltage Drop Calculator

US / Canada AWG Standard
Minimum Wire Size
6 AWG
Copper (75°C NEC)
Breaker / Fuse Size
60 Amp
Includes 125% NEC factor
Voltage Drop
1.29%
PASS (Under 3% NEC limit)
Total Power
11.52 kW
Max Circuit Load

🛒 Complete Installation Materials Checklist

1. Recommended Wire
6/3 NM-B Copper Wire Roll (50-100 ft)
Check Wire Price →
2. Breaker / Disconnect
60 Amp Subpanel Load Center Box
Check Breaker Price →
3. Compatible Equipment
60 Amp 2-Pole Feeder Breaker
View on Amazon →

📋 NEC Code & Installation Notes

  • Under NEC 240.4(B), 6/3 NM-B copper (55A rating) can be protected by a 60A breaker if the calculated load does not exceed 55A.
  • For a full 60A continuous rating, pull 6 AWG THHN copper in conduit or use 4-4-4-6 Aluminum SER.
  • Requires 4 conductors: two hots, one neutral, and one equipment ground.

Frequently Asked Questions

What wire gauge do I need for 60 amp subpanel wire size for 60 feet (shed / garage)?
For a 60A load at 240V over 60 feet, the recommended conductor is 6 AWG Copper (6/3 NM-B) or 4 AWG Aluminum paired with a 60 Amp 2-Pole Breaker to meet NEC ampacity and keep voltage drop below 3%.
Can I use aluminum wire instead of copper for 60 Amps?
Yes, for feeder runs (such as subpanels or RV pedestals), aluminum THHN/XHHW or SER cable can be used if upsized by 1 to 2 AWG sizes (check the Aluminum option in our calculator above) and terminated with anti-oxidant compound on AL-rated lugs.
Why does distance affect wire size for 60A 240V Subpanel Feeder?
Longer wire runs increase electrical resistance, causing voltage drop. Under NEC guidelines, keeping voltage drop under 3% prevents overheating, nuisance breaker trips, and reduced charging or motor efficiency.